Design standards: GB4706 Safety of household and similar electrical appliances Part 1: General requirements GB/T5169.10 Fire hazard testing for electrical and electronic products Part 10: Basic test methods for glow wire/glow wire devices and general test methods.
Compliant with standards: IEC60695-2-10/11/12/13,IEC60884-1,GB2099.1,IEC60335-1,GB4706.1,VDE,GB/T5169.10 Wait.
Technical parameter
Glow wire temperature: 500~1000 ºC± 2 ºC, continuously adjustable.
Burning time: 0-999.9s ± 0.1s, adjustable (usually selected as 30s)
Ignition time: 0-999.9s ± 0.1s, automatically recorded, manually paused.
Extinguishing time: 0-999.9s ± 0.1s, automatically recorded, manually paused.
Thermocouple: Imported armored (K-type) thermocouple with a diameter of 1mm.
Glow wire: Nickel chromium wire with a diameter of 4 mm.