SD-MW-02 Safety Hat Net Ultraviolet Rays Aging Box Testing Machine
Host structure
1.Large test chamber, can be put in fourteen safety helmets and two 1mx1m safety net samples at once.
2.The safety helmet sample holder can rotate 360 ° for easy installation.
3.The ultraviolet light source adopts a 450W short pulse high-pressure xenon lamp, matched with a power trigger to ensure the stability of the light source.
4.Adopting an air cooling system with "bottom inlet and top outlet". The dedicated turbine fan ensures that the external wind energy flows uniformly through the surface of the xenon lamp and the inside of the test chamber, ensuring that the temperature does not exceed the standard requirement of 60 ºC and extending the service life of internal components.
Main purpose
Produced according to GB/T6096-2009, GB6095-2009, and GB5725-2009, it is mainly used for UV pre-treatment before safety net and seat belt experiments. It is widely used in special labor protection equipment supervision and inspection stations, building science research institutes, and construction engineering quality inspection stations.
Main indicator
1.UV light source: 450W short pulse high-pressure xenon lamp.
2.Timing range: 0-999 hours. The touch screen can be set by oneself with automatic alarm.
3.Temperature range: 0-60 ºC. The touch screen can be set by oneself and an over temperature alarm will be triggered.
4.Sample quantity of safety helmets: 1-14 safety helmets, including 3 at the bottom, 3 at the top, and 8 in the middle. Spherical distributed structure.
5.Distance between the safety helmet and the lamp: standard distance of 150±5mm, and equipped with a dedicated testing ruler.
6.Number of safety net samples: 2 maximum 1mx1m samples, symmetrically distributed on both sides.
7.Distance between safety net and the lamp: standard distance of 400±20mm, and equipped with a dedicated testing ruler.
8.Equipment power supply: AC220V, 50HZ.
9.Weight: Approximately 150Kg